Reproduction steps:
1. Open the attached “Test Project” project
2. Select “SerializedFieldBug” in the Hierarchy window
3. Select “Serialized Field Bug (Script)” Component and change the “Serialized Transform” value to anything in the Scene
4. Change back the “Serialized Transform” value to “None”
Expected result: “None” value displays no icon
Actual result: “None” value displays the previous icon (Transform icon)
Reproducible with: 2022.2.0a9, 2022.2.2f1, 2023.1.0a25, 2023.2.0a2
Not reproducible with: 2020.3.44f1, 2021.3.16f1, 2022.2.0a8
Reproducible on: Windows 10
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- ScrollView clips content when under an ancestor that has a filter set
- "Retrieving array element that was out of bounds" error thrown when attempting to remove a column from a Multi-Column List View
- Multi-Column List View horizontal scroll resets to left most position when scrolling vertically
- Floating License is lost for concurrent jobs
- Warning "Failed to insert item" is logged when Assigning Project to Organization's Project in the Project Settings
Resolution Note (fix version 2023.3):
This PR has landed in trunk - Unity 2023.3.0a1