Search Issue Tracker

Fix In Review for 12.0.0

Votes

0

Found in [Package]

10.4.0

Issue ID

1346698

Regression

No

[Shadergraph][HDRP] Entry field for HD Lit "Sorting Priority" auto-cancels after a single digit

Package: Scriptable Render Pipeline HD

-

Reproduces in HDRP 10.4.0
Reproduces in SRP2Core for Version: 2021.1.8f1.2516
Does not reproduce in SRP 7.6.0 (likely because no Internal Inspector)
Does not reproduce with SRP2Core for Version: 2021.2.0b1.3029

Repro steps:
1. Create an HD Lit shadergraph
2. In internal inspector, set Surface Type to transparent
3. Click the field for "Sorting Priority"
4. Attempt to type "50"
Expected result: it lets you type the whole number
Actual result: the field entry stops after you type a single digit (only letting you type 5)

Add comment

Log in to post comment