Search Issue Tracker
Fixed in 1.0.0-pre.3
Votes
0
Found in [Package]
0.4.3-preview.1
Issue ID
1401543
Regression
Yes
[Memory Profiler] Location of the Snapshot A Memory Bars are slightly moving forward when switching between Snapshot
How to reproduce:
1. Open the user's attached "case_1401543" project
2. Open the "Window -> Analysis -> Memory Profiler" window from the menu
3. Select the "Test1" and "Test2" Snapshot under the Compare Snapshots pane
4. Select the switch button to switch between the Snapshots
Expected result: Snapshot A and B Memory Bars location doesn't change, except for being swapped
Actual result: Snapshot A and B Memory Bars get swapped, and the Memory Bars of the Snapshot A slightly gets longer
Reproducible with: 0.4.3-preview.1, 0.5.0-preview.1 (2019.4.36f1, 2020.3.30f1, 2021.2.13f1, 2022.1.0b9, 2022.2.0a5)
Not reproducible with: 0.4.2-preview.1 (2019.4.36f1, 2020.3.30f1, 2021.2.13f1, 2022.1.0b9, 2022.2.0a5)
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- Incorrect rotations on bones when importing FBX animations with a Humanoid Rig
- Render Graph Viewer “Pass List” section is flickering when resizing vertically and the Render Graph Viewer window is docked
- Render Graph Viewer Capture button plays the click animation but does not do anything when the Capture button is pressed with the “Enter” key on the keyboard
- UI Builder Scrollview is unable to scroll all the way down when the window is downsized vertically
- Celestial bodies order remains unchanged when the Distance setting is modified
Resolution Note (fix version 1.0.0-pre.3):
Postponing for more urgent work. Feature removed.