Search Issue Tracker
Fixed
Fixed in 2022.2.0b3, 2023.1.0a1
Votes
0
Found in
2022.2.0a17
Issue ID
UUM-1574
Regression
Yes
[Linux][Profiler] Profiling mode dropdown remains open after closing the Profiler window
Steps to reproduce:
1. Open a new or an existing project
2. Open Profiler window (Window -> Analysis -> Profiler)
3. Click on the Profiling mode dropdown to expand it
4. Close Profiler window
Expected results: Profiler window is closed together with any subwindows called from it
Actual results: Profiling mode dropdown remains open
Reproducible with: 2021.2.0a18, 2021.2.8f1, 2022.1.0b6, 2022.2.0a2
Not reproducible with: 2020.3.26f1, 2021.2.0a17 (different dropdown menu)
Notes:
- Tested with Ubuntu 20.04
- Not reproducible on Mac
- If one of the profiling modes is selected in the remaining dropdown window, upon opening Profiler and expanding the dropdown again this warning is produced: "Should not be capturing when there is a hotcontrol"
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- Manual reference page for Grid Selection is missing
- Awaitable.NextFrameAsync causes GC Alloc 0.7 KB when using CancellationToken
- Prefab "Overrides" list item popups are overridden when navigating with keyboard arrow keys
- Alpha Tolerance setting does not affect generated outlines when generating Custom Physics Shape in the Sprite Editor
- The information/help message section misses a margin in the "Profiler" window
Resolution Note (fix version 2022.2.0b3):
https://ono.unity3d.com/unity/unity/pull-request/145182/_/2022.2/backport/platform/editor/linux/close-dropdown-profiler-uum6864