Search Issue Tracker

Fixed in 2.2.10, 2,3,5

Votes

0

Found in [Package]

2.2.8

Issue ID

1162074

Regression

Yes

Camera controlled by Cinemachine Framing Transposer will only reach half of Maximum Ortho Size

Package: Cinemachine

-

How to reproduce:
1. Open attached project "case_1162074-MaxOrthoSize.zip" and scene "SampleScene"
2. In Hierarchy window, select "CM vcam1"
3. In Inspector window, observe "Maximum Ortho Size" value (its '5' in my example)
4. In Hierarchy window, select "Main Camera"
5. In Inspector window, observe "Camera" -> "Size"

Expected result: the size value is 5
Actual result: the size is 2.5, half of the "Maximum Ortho Size"

Reproducible with: 2018.3.0b1 (2.2.8), 2018.3.14f1 (2.2.9), 2018.4.2f1 (2.2.9), 2019.3.0a6 (2.3.3, 2.3.4)
Not reproducible with: 2018.3.0b1 (2.1.13, 2.2.0, 2.2.7)
Could not test with: 2018.3.0b1 (2.1.12) and older due to package manager errors