Search Issue Tracker

Won't Fix

Votes

3

Found in [Package]

1.3.X - Entities

7000.0.0a1

Issue ID

ECSB-1094

Regression

No

All Inspectors are affected and one of them rendered blank when changing the Entities Inspector data mode

Package: Entity Component System (ECS)

-

How to reproduce:
1. Open the user-attached project “findBug_ECSinspectorMode”
2. Open the “SampleScene” scene
3. In the Inspector open the three-dot menu → Add Tab → Inspector to open the second Inspector
4. Change the Layout so two Inspectors are visible at once
5. In the Hierarchy under the subscene “SubScene” select the “Cube” GameObject
6. In one of the Inspectors change the data mode to “Runtime” (Circle near the lock icon in the right-upper corner)
7. Observe the Inspectors

Expected results: Only the Inspector where the data mode was changed is affected
Actual results: Both of the Inspectors are affected and the second one is rendered blank

Reproducible with: 1.0.16 (2022.3.29f1), 1.2.0, 1.2.1 (2022.3.29f1, 6000.0.2f1)
Can’t test with: 2021.3.38f1 (Package versions are not available)

Reproducible on: Windows 11 Pro
Not reproducible on: No other environment tested

  1. Resolution Note:

    There are no fixes planned for this Bug

Comments (1)

  1. martin_noble

    May 17, 2024 10:58

    I am currently staying on Unity 2022.3.24f1 with Entities 1.2.1, since this issue seems to only be ocurring on Unity versions later that that.

Add comment

Log in to post comment

All about bugs