Search Issue Tracker

Fixed

Fixed in 2022.3.63f1, 6000.0.51f1, 6000.1.5f1, 6000.2.0b4, 6000.3.0a1

Votes

0

Found in

2022.3.61f1

6000.0.47f1

6000.1.0b15

6000.2.0a9

6000.3.0a1

7000.0.0a35

Issue ID

UUM-103066

Regression

No

[Overlays] When Reverting all Presets or deleting the currently chosen Preset the Overlay Preset is not switched to the Default Preset

-

*Steps to reproduce:*
# Open any Project
# In Scene View open the Overlay Menu ( ` )
# Click on the dropdown menu "Default" > Save Preset or Save Preset to File and create a Preset
# Now from the same dropdown menu select "Delete Preset"
# Manually switch to the "Default" Preset
# Create another Preset and from the dropdown menu select "Revert All Presets"

*Actual results:* The Preset that is currently selected and then Deleted or when deleting and reverting all presets they are not switched to the Default Preset

*Expected results:* -The Default Preset is set as current Preset when deleting the currently selected Preset, the same should happen, as the pop-up implies, when the option "Revert All Saved Presets" is selected by the user-

Deleting the currently selected preset to change the preset selection to Default but preserve the current (unsaved) layout of overlays. 

Revert All Saved Presets should switch to the Default preset.

*Reproducible with versions:* 2022.3.61f1, 6000.0.47f1, 6000.1.0b15, 6000.2.0a9

*Tested on (OS):* Windows 11

  1. Resolution Note:

    Postponing 7 ports

Add comment

Log in to post comment