[Serialization] Private fields in Network Command does not get serialized using SerializeField attribute
Steps to reproduce:
1. Download and import attached project. (repro-case_752995-SendeMessage.zip)
2. Play in the editor and do not stop it.
3. Build and run standalone build.
4. Press 'A' in the keyboard on the standalone build.
5. Inspect the Console in the Editor.\
Expected result: ".. privateString: works"
Actual result: ".. privateString: does not work"
Reproduced on: 5.4.0a5, 5.3.0f4, 5.2.4f1
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- Required SpriteMask class (ID 331) is stripped when "Strip Engine Code" is enabled
- “Maximized serialized file backup not found” error is thrown when minimizing a window in a newly opened project
- Build stack trace contains invalid lines when building with IL2CPP using scripts with delegates containing generic types in the signature
- Entities Systems window has a “Show Full Player Loop” dropdown which does nothing when clicked after enabling “Show Full Player Loop”
- Entities Hierarchy Search “Show/Hide” button’s Lens Icon is blurry when the Editor is on an external monitor
Resolution Note:
We really appreciate your contribution to the Unity product. Thank you for reporting this issue. We take every case submitted to us seriously by investigating the impact on you, our customer, as well as the impact it may have on the engineering and experience of our product.
This particular case has been investigated thoroughly and we have decided, in the interests of protecting the stability and features of Unity for users that rely upon the affected versions, to not address this issue.