Search Issue Tracker
Fixed
Fixed in 2021.3.33f1, 2022.3.13f1, 2023.2.0b17, 2023.3.0a13
Votes
0
Found in
2021.3.28f1
2022.3.5f1
2023.1.5f1
2023.2.0a23
2023.3.0a3
Issue ID
UUM-42938
Regression
No
ObservableList is half-cleared when using the Clear method
Reproduction steps:
1. Open the “ObservableListClear“ project
2. Open the “Sample” scene
3. Enter Play Mode and observe the Console
Expected result: “0” is logged
Actual result: “2” is logged
Reproduced in: 2021.3.0f1, 2021.3.28f1, 2022.3.5f1, 2023.1.5f1, 2023.2.0b1
Reproduced using: macOS 13.4.1 (Intel), Windows 11
Note: Also reproduced in Player
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.