How to reproduce:
1. Open the attached project “Lightprobe”
2. Open the scene “st_02_00“
3. In the Lighting window change the Lightmapper field to Progressive CPU and Generate Lighting
4. Change the Lightmapper field to Progressive GPU (Preview) and Generate Lighting
5. Observe the result
Expected result: The Light Probe is generated the same way (The Sphere is in the shadows, so it should be dark)
Actual result: The Light Probe is generated incorrectly using Progressive GPU (Preview)
Reproduced with: 2021.3.6f1, 2022.1.5f1, 2022.2.0b1, 2023.1.0a1
Could not test with: 2019.4.38f1, 2020.3.36f1 (Compilation errors)
Reproduced on: Windows 11 Pro
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- Reflection problems when unbaked Reflection Probes are present
- Light Explorer columns sorting arrow is too small
- Context menu actions (Collapse All, Expand All, Enable All, Disable All, Remove All, Reset All) do nothing in Volume component
- [Android] Audio volume decreases when returning to the app during screen recording
- Graphical issues are caused by GPU Occlusion Culling when using Amplify Shaders
Resolution Note:
It is not possible to reproduce this issue due to a broken reproduction project.