Search Issue Tracker
By Design
Votes
0
Found in [Package]
4.0.0
Issue ID
1408174
Regression
No
[Adaptive Performance] Thermal Sample does not show thermal information
Reproduction steps:
1. Open project in "My project (1).zip"
2. Build and Deploy "Thermal" Scene to a device
3. Inspect the information in the running application (top left)
Expected result: temperature indicator indicates temperature, if the device gets hot a warning is displayed
Actual result: the temperature indicator does not move even if the device is hot to the touch
Tested on:
ASUS_X018DC, Android 7.0, MT6750 1.51GHz, Mali-T860
Intel(R) Xeon(R) W-2295 CPU @ 3.00GHz; NVIDIA GeForce RTX 3070 Ti NVIDIA GeForce RTX 3070 Ti; Windows 10
Reproducible with: 4.0.0 (2021.2.15f1, 2022.1.0b11, 2022.2.0a7)
Could not test with: 2019.4.36f1, 2020.3.29f1 (because of errors (does not contain definition for...))
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- Editor UI Text is displayed incorrectly or blank, and "Unable to load font face for [System Normal]." and other warnings are spammed when Editor Font is set to System Font and TMP Package is imported
- TabView with icons is smaller in height then other tabs with text
- [iOS] Error shows and "Microphone.GetPosition" logged as zero when "Microphone.Start()" is called the first time while a microphone is busy in another app and the second time when the microphone is released
- "Check for Updates" Fails to Connect to Update Server
- "Validation: Write range..." errors when creating and destroying GraphicsBuffer rapidly in WebGPU
Resolution Note:
Currently, Thermal Sampling only works on Samsung devices.