Search Issue Tracker
By Design
Votes
0
Found in [Package]
4.0.0
Issue ID
1408174
Regression
No
[Adaptive Performance] Thermal Sample does not show thermal information
Reproduction steps:
1. Open project in "My project (1).zip"
2. Build and Deploy "Thermal" Scene to a device
3. Inspect the information in the running application (top left)
Expected result: temperature indicator indicates temperature, if the device gets hot a warning is displayed
Actual result: the temperature indicator does not move even if the device is hot to the touch
Tested on:
ASUS_X018DC, Android 7.0, MT6750 1.51GHz, Mali-T860
Intel(R) Xeon(R) W-2295 CPU @ 3.00GHz; NVIDIA GeForce RTX 3070 Ti NVIDIA GeForce RTX 3070 Ti; Windows 10
Reproducible with: 4.0.0 (2021.2.15f1, 2022.1.0b11, 2022.2.0a7)
Could not test with: 2019.4.36f1, 2020.3.29f1 (because of errors (does not contain definition for...))
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- "Shader warning in 'Hidden/Light2D': implicit truncation of vector type" is thrown when building Universal 2D template
- AI Assistant breaks compilation of packages using System.Runtime.CompilerServices.Unsafe via auto-referencing
- Unity Hub checks the "Documentation" module by default on the 6.4 and 6.5 streams despite that it was unchecked with the previous installs
- Shortcut that toggles between Dopesheet and Curves Views in the Animation Window's Timeline is mislabed
- Property List Items Overlap onto the Property List's top edge when scrolling through a long Property List
Resolution Note:
Currently, Thermal Sampling only works on Samsung devices.