Search Issue Tracker
Fixed in 2020.2.X
Fixed in 2019.3.X, 2020.1.X
Votes
0
Found in
2017.4
2019.3.3f1
2020.2
Issue ID
1225682
Regression
No
Current Frame Button looks active when data in Profiler Window is cleared
How to reproduce:
1. Create a new project
2. Open Profiler Window
3. Enter Play Mode -> Pause
4. In Profiler Window Clear all profiling data
Expected result: Current Frame button is inactive upon clearing data in Profiler Window
Actual result: Current Frame Button looks active upon clearing data in Profiler Window
Reproducible with: 2017.4.37f1, 2018.4.19f1, 2019.3.5f1, 2020.1.0b1, 2020.2.0a2
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- Long Prefab save times when using Unity 2022.2 and higher
- Console displays error "UnityException: Creating asset at path Assets/Scenes/ .scenetemplate failed." during scene template saving
- "Development Build" watermark is shown in non-development UWP release builds
- Console errors appear when the Inspector is set to Debug and a GameObject is selected
- A script public variable value is not used when set in the Inspector window
Resolution Note (fix version 2020.2):
Fixed in: 2020.2.0a5
Resolution Note (fix version 2020.1):
Fixed in: 2020.1.0b9
Resolution Note (fix version 2019.3):
Fixed in: 2019.3.14f1